Blower Motor — B1340021S, 1/3HP, Direct Drive
Open DrawingPart Number: B1340021S Part Name: BLOWER MOTOR 1/3 HP, DIRECT DRIVE B1368034S BLOWER WHEEL 10 X 6 Open Drawing Part Number: B1368034S Part Name: BLOWER WHEEL 10 X 6. 2) Rowhouse, brick, 3-levels above ground, built around 1900 +/-3) Goodman GMP075-3. Board is B18099-13. 5) n/a - not a boiler. 6) n/a - not a boiler. 7) Was a Home Depot 'rite-temp'. Is now two wires sticking out of my wall tied together. 8) More details above! Any help would be greatly appreciated. Collection of goodman gas furnace wiring diagram. A wiring diagram is a streamlined standard pictorial depiction of an electrical circuit. It shows the parts of the circuit as simplified shapes, as well as the power as well as signal connections between the gadgets.
The Goodman literature library has consumer brochures and technical specifications for various Goodman HVAC models and product lines.
$188.95Quantity:
Vent/Inducer Motor — B1859005
Circuit Board — B1809913S Furnace Control Board
Gas Valve — 0151M00013S / B1282628, Single Stage
$67.99Quantity:
Hot Surface Ignitor — 0230K00001
$56.99Quantity:
Incoming search terms:
- gmp075-3
- gmp075-3 parts
- goodman gmp075-3
- gmp075-3 blower motor
- gmp075-3 ignitor
- gmp075-3 gas furnace
- POST a QUESTION or COMMENT about where to find furnace or boiler installation and service or maintenance manuals and guides
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
Manuals, parts lists, wiring diagrams for Goodman & Aman a HVAC equipment:
Free downloadable manuals for Air Conditioners, Boilers, Furnaces, Heat Pumps. Here we provide free downloadable copies of installation and service manuals for heating, heat pump, and air conditioning equipment, or contact information for the manufacturer.
We also provide a MASTER INDEX to this topic, or you can try the page top or bottom SEARCH BOX as a quick way to find information you need.
Goodman Heaters, Furnaces, Air Conditioners, Furnaces Manuals & Troubleshooting
Goodman HVAC - also Amana Manuals & Error Code Table
[Click to enlarge any image] Goodman Global and Goodman Manufacturing, founded in 1982, is currently (2017) a member of the Daikin Group, Osaka, Japan, after being purchased in 2012. Goodman produces residential and commercial HVAC equipment.
- Goodman HVAC Contact Information:
Goodman Heating & Air Conditioning, 7401 Security Way Houston, TX 77040 USA Tel: 1-877-254-4729 (USA) www.goodmanmfg.com - or - www.amana-hac.com
Website: http://www.goodmanmfg.com/
also see DAIKIN GLOBAL - SERVICE PARTS DEPARTMENT GOODMAN MANUFACTURING CO., LP 1501 SEAMIST HOUSTON, TEXAS 77008 USA Tel: (713) 861 - 2500
- Also see AMANA HVAC EQUIPMENT for manuals for older AMANA HVAC air conditioners etc. Amana HVACR products that are manufactured by Goodman Global.
- GOODMAN AC SERIES 10-12 SEER CEILING-MOUNT AIR CONDITIONER [PDF] Manual
- GOODMAN AIR CONDITIONING SPLIT SYSTEM CKL CLJ CRT CLT TWC CLQ HDC and CPLE CPLJ CPRT CPLT & HDP Manual [PDF] AHCP service manual
- GOODMAN AVPTC-14 AIR HANDLER INSTALL & OPERATION MANUAL [PDF] (2013),
- GOODMAN & AMANA R-22 SPLIT SYSTEM A/C SERVICE MANUAL [PDF] 2005-2009 R-22, GSC-series Goodman and Amana Brand split condenser units, ASC series, GSH series, ASH series, VSH series units.
- GOODMAN & AMANA R-410A SYSTEM SERVICE MANUAL [PDF] 2006-2009 SX & SZ series blowers, coils, condensers
- GOODMAN ARUF ARPF ADPF AEPF SERIES AIR HANDLER INSTALLATION & OPERATING INSTRUCTIONS [PDF] (2006)
- GOODMAN R-22 CK-Series SERVICE INSTRUCTIONS [PDF] (2006) CKL CLJ CRT CLT TWC LQ HDC split system remote coolers & CPLE CPLJ CPRT CPLT HDP Split System remote heat pumps using R22, blower, coil, accessory repair
- GOODMAN TWO STAGE GAS FURNACE CV96 & MVC96 [PDF] Installation & Operating Manual, (Type FSP CATEGORY IV Direct or Non Direct Vent Air Furnace)
- GOODMAN GAS FURNACE IO MANUAL GMP GMPE [PDF] power vented multi-position (2001) Goodman Manufacturing Company, LP 2550 North Loop West, Suite 400 Houston, Texas 77092 USA
This manual includes helpful chimney/vent sizing tables giving vent diameter, height, rise, and vent capacity. - GOODMAN GAS FURNACE IO MANUAL GMS8 GDS8 GHS8 [PDF] (2005) Gas-Fired Warm Air Furnace, Single Stage, Category 1, Goodman Manufacturing Co., L.P.
- GOODMAN FURNACE High Temperature Plastic Vent HTPV safety recall US CPSC notice
- Also see Goodman Furnace High Temperature Plastic Vent HTPV safety recall US CPSC notice
- Also see JANITROL HVAC
Goodman GMP & Other Gas Furnace Status Light Flash Fault Codes
A (usually red) LED is visible through an opening in the front of your Goodman furnace, typically just above a data tag. This table decodes the various LED lamp flash trouble codes.
Goodman Status Light / LED Error Codes | ||
Trouble Code Indicator | Meaning | Repair |
On Solid | no connection from the thermostat | check thermostat wiring, setting, function |
1 Flash on/off | Furnace ignition failure Locks out after 3 ignition attempts. | Automatically resets after 1 hour. or Turn off power or turn down thermostat for 30 seconds then restore power / thermostat setting |
2 Flashes | Draft inducer / blower failure or pressure switch failure (short circuit) | Check for shorted wires; Replace pressure switch. |
3 Flashes | Open pressure switch circuit or draft inducer running when it should not be. Heating mode: The vent pressure (vacuum) switch will close when it detects a pressure in excess of it’s setting. If the pressure switch fails to close the status light will flash three (3) times. The sequence cannot continue until the pressure switch closes. | Check pressure switch hose for crimping; Check for improper or loose wiring. |
4 Flashes | Primary limit circuit open | Bad, loose, corroded electrical connection, dirty air filter, blocked exhaust flue. Clean or replace air filters. Safety check exhaust flue. |
5 Flashes | Flame present but no call for heat | Check for gas leaks Check for improper / delayed burner shut-down |
6 Flashes | Reversed polarity (some models) | Check power supply wiring vs wiring diagram |
7 Flashes | Low flame or weak flame sensor signal | Check gas supply pressure vs data plate pressure Check / replace dirty corroded flame sensor probe Check flame sensor mounting/location |
8 Flashes | Igniter circuit failure | Check igniter wiring connections; check for bad ground connection; Replace defective igniter. |
9 Flashes | Open high state pressure switch Switch not closing during high-stage draft inducer blower operation | Inspect pressure switch hose for crimping Check for loose electrical connection at switch |
Continuous rapid flashing | 120VAC power supply polarity reversed | Check wiring diagram; fix wiring polarity |
...
Continue reading at MANUALS for HEATING SYSTEM CONTROLS or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see these
Recommended Articles
- AGE of WATER HEATERS - data tag decoding, contact information for water heater manufacturers, water heater manuals
- AIR CONDITIONING & HEAT PUMP SYSTEMS - home
- BOILERS, HEATING - home
- DATA TAGS on AIR CONDITIONERS for help decoding the equipment age and other specification
- FURNACES, HEATING - home
- GUIAS & MANUALES SISTEMS MECANICOS in Spanish
- MANUALS & PARTS GUIDES - HVAC - home - Master Index to All Brand Names & HVAC manuals, wiring diagrams, installation and repair guides
Suggested citation for this web page
GOODMAN HVAC MANUALS & ERROR CODES at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
INDEX to RELATED ARTICLES: ARTICLE INDEX to AIR CONDITIONING & HEAT PUMPS
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Or see
INDEX to RELATED ARTICLES: ARTICLE INDEX to HEATING SYSTEMS
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
...
Ask a Question or Search InspectApedia
Questions & answers or comments about where to find furnace or boiler installation and service or maintenance manuals and guides
Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.
Search the InspectApedia website
Note: appearance of your Comment below may be delayed:if your comment contains an image, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Apologies for the delay.
Technical Reviewers & References
- ...
Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair
Goodman Model Gmp075 3
- Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the InspectAPedia Bookstore. Also see our Book Reviews - InspectAPedia.
- ...
Gmp075 3 Specs
- Carson, Dunlop & Associates Ltd., 120 Carlton Street Suite 407, Toronto ON M5A 4K2. Tel: (416) 964-9415 1-800-268-7070 Email: info@carsondunlop.com. The firm provides professional HOME INSPECTION SERVICES and also extensive HOME INSPECTION EDUCATION and home inspection-related PUBLICATIONS. Alan Carson is a past president of ASHI, the American Society of Home Inspectors.
Thanks to Alan Carson and Bob Dunlop, for permission for InspectAPedia to use text excerpts from The Home Reference Book & illustrations from The Illustrated Home. Carson Dunlop Associates' provides extensive home inspection education and report writing material.
The ILLUSTRATED HOME illustrates construction details and building components, a reference for owners & inspectors.
Special Offer: For a 5% discount on any number of copies of the Illustrated Home purchased as a single order Enter INSPECTAILL in the order payment page 'Promo/Redemption' space.
TECHNICAL REFERENCE GUIDE to manufacturer's model and serial number information for heating and cooling equipment, useful for determining the age of heating boilers, furnaces, water heaters is provided by Carson Dunlop Weldon & Associates
Special Offer: Carson Dunlop Associates offers InspectAPedia readers in the U.S.A. a 5% discount on any number of copies of the Technical Reference Guide purchased as a single order. Just enter INSPECTATRG in the order payment page 'Promo/Redemption' space. - The HOME REFERENCE BOOK - the Encyclopedia of Homes, Carson Dunlop & Associates, Toronto, Ontario, 25th Ed., 2012, is a bound volume of more than 450 illustrated pages that assist home inspectors and home owners in the inspection and detection of problems on buildings. The text is intended as a reference guide to help building owners operate and maintain their home effectively. Field inspection worksheets are included at the back of the volume.
Special Offer: For a 10% discount on any number of copies of the Home Reference Book purchased as a single order. Enter INSPECTAHRB in the order payment page 'Promo/Redemption' space. InspectAPedia.com editor Daniel Friedman is a contributing author.
Or choose the The HOME REFERENCE eBook for PCs, Macs, Kindle, iPad, iPhone, or Android Smart Phones.
Special Offer: For a 5% discount on any number of copies of the Home Reference eBook purchased as a single order. Enter INSPECTAEHRB in the order payment page 'Promo/Redemption' space. - Building inspection education & report writing systems from Carson, Dunlop & Associates Ltd
COMMERCIAL BUILDING INSPECTION COURSES - protocol ASTM Standard E 2018-08 for Property Condition Assessments
HOME INSPECTION EDUCATION COURESES (Canada)
HOME INSPECTION EDUCATION COURSES (USA) including home study & live classes at eleven colleges & universities.
HOME INSPECTION EDUCATION: HOME STUDY COURSES - ASHI@Home Training 10-course program.
Special Offer: Carson Dunlop Associates offers InspectAPedia readers in the U.S.A. a 5% discount on these courses: Enter INSPECTAHITP in the order payment page 'Promo/Redemption' space. InspectAPedia.com editor Daniel Friedman is a contributing author. - The Horizon Software System manages business operations,scheduling, & inspection report writing using Carson Dunlop's knowledge base & color images. The Horizon system runs on always-available cloud-based software for office computers, laptops, tablets, iPad, Android, & other smartphones